BioMall
Brand Store/Takara/AcGFP Flow Cytometer Calibration Beads
AcGFP Flow Cytometer Calibration Beads
GENERAL CATALOGUE

AcGFP Flow Cytometer Calibration Beads

632594 · 20 Assays

Takara · Cat: 632594

Reach 3+ verified distributors

Catalog No: 632594
Category: Fluorescent proteins
Pack Size: 20 Assays
Brand: Takara

Description

The AcGFP Flow Cytometer Calibration Beads allow for easy calibration of any flow cytometer with a 488 nm laser line that excites the green fluorescent proteins AcGFP1 Aequorea coerulescensGFP and EGFP. The excitation/emission spectrum and brightness of AcGFP are almost identical to those of EGFP. The beads consist of a mixture of six distinct populations that vary in the number of attached AcGFP1 molecules, giving each population a distinct fluorescent signature. The value for the corresponding Molecular Equivalent of Soluble Fluorophore MESF per peak was determined by correlating the fluorescence intensity of each respective bead population with the amount of soluble AcGFP1 yielding the same fluorescence intensity. The lowest intensity represents the autofluorescence signal of cells not expressing green fluorescent protein, while the five remaining peaks are evenly distributed over the remaining scale of the green fluorescence detection channel. Our products are to be used forResearch Use Only. They may not be used for any other purpose, including, but not limited to, use in humans, therapeutic or diagnostic use, or commercial use of any kind. Our products may not be transferred to third parties, resold, modified for resale, or used to manufacture commercial products or to provide a service to third parties without our prior written approval. Back Flow cytometer analysis of AcGFP Flow Cytometer Calibration Beads. 20 mul of the AcGFP Flow Cytometer Calibration Bead suspension was thorougly resuspended in 1 ml of 1X Flow Cytometer Calibration Beads Dilution Buffer. The bead suspension was then analyzed on a FACS Calibur BD flow cytometer using the 488 nm laser line and detecting green fluorescence in the FL-1 channel. 60,000 events were analyzed. The obtained graph shows that the bead suspension contains six well-distinguished populations with different fluorescent intensities. Back

More from Takara

pIRES2 DsRed-Express2 Vector
pIRES2 DsRed-Express2 Vector
632540
Fluorescent proteins
pmPlum Vector
pmPlum Vector
632527
Fluorescent proteins
pAcGFP1-C2 Vector
pAcGFP1-C2 Vector
632481
Fluorescent proteins
pDsRed2-Nuc Vector
pDsRed2-Nuc Vector
632408
Fluorescent proteins
pAmCyan Vector
pAmCyan Vector
632440
Fluorescent proteins
pmRaspberry Vector
pmRaspberry Vector
632526
Fluorescent proteins
pHcRed1-N1/1 Vector
pHcRed1-N1/1 Vector
632424
Fluorescent proteins
Lenti-XTM Actin Dynamics Monitoring Kit
Lenti-XTM Actin Dynamics Monitoring Kit
631076
Fluorescent proteins