BioMall
Brand Store/BDB Bioscience/BD HorizonTM RB613 Mouse Anti-Human CD197 (CCR7)
B
GENERAL CATALOGUE

BD HorizonTM RB613 Mouse Anti-Human CD197 (CCR7)

571209 · 100 Tests

BDB Bioscience · Cat: 571209

₹350 – ₹550 approx.This price excludes freight and taxes. Please RFQ to get the final price.

Reach 3+ verified distributors

Catalog No: 571209
Category: reagents
Pack Size: 100 Tests
Brand: BDB Bioscience

Description

Multicolor flow cytometric analysis of CD197 CCR7 on Human peripheral blood leukocytes and lymphocytes Human whole blood was stained with BD Horizon BV421 Mouse Anti-Human CD4 Cat. No. 562424 , BD Horizon BUV395 Mouse Anti-Human CD8 Cat. No. 563795 , APC Mouse Anti-Human CD45RA Cat. No. 550855 antibodies, and with either BD Horizon RB613 Mouse IgG1, kappa Isotype Control Cat. No. 571106 or BD Horizon RB613 Mouse Anti-Human CD197 CCR7 antibody Cat. No. 571209/571213 . The erythrocytes were lysed with BD FACS Lysing Solution Cat. No. 349202 . Flow cytometry and data analysis were performed using a BD FACSymphony A5 SE Cell Analyzer System and FlowJo Software. Plots 1 and 2: The bivariate pseudocolor density plots showing the correlated expression of CD197 CCR7 or Isotype control staining versus side light-scatter SSC-A signals were derived from gated events with the forward and side light-scatter characteristics of intact leukocytes. Plot 3: The two-parameter pseudocolor density plot showing the correlated expression of CD197 CCR7 versus CD45RA was derived from CD4-positive T cell gated events with the forward and side light-scatter characteristics of intact lymphocytes. Please note that we have observed considerable donor-to-donor variation in the proportion of CD197 CCR7 -negative CD4-positive lymphocytes. Plot 4: The two-parameter pseudocolor density plot showing CD197 CCR7 staining versus CD45RA was derived from CD8-positive T cell gated events with the forward and side light-scatter characteristics of intact lymphocytes. Multicolor flow cytometric analysis of CD197 CCR7 on Human peripheral blood leukocytes and lymphocytes Human whole blood was stained with BD Horizon BV421 Mouse Anti-Human CD4 Cat. No. 562424 , BD Horizon BUV395 Mouse Anti-Human CD8 Cat. No. 563795 , APC Mouse Anti-Human CD45RA Cat. No. 550855 antibodies, and with either BD Horizon RB613 Mouse IgG1, kappa Isotype Control Cat. No. 571106 or BD Horizon RB613 Mouse Anti-Human CD197 CCR7 antibody Cat. No. 571209/571213 . The erythrocytes were lysed with BD FACS Lysing Solution Cat. No. 349202 . Flow cytometry and data analysis were performed using a BD FACSymphony A5 SE Cell Analyzer System and FlowJo Software. Plots 1 and 2: The bivariate pseudocolor density plots showing the correlated expression of CD197 CCR7 or Isotype control staining versus side light-scatter SSC-A signals were derived from gated events with the forward and side light-scatter characteristics of intact leukocytes. Plot 3: The two-parameter pseudocolor density plot showing the correlated expression of CD197 CCR7 versus CD45RA was derived from CD4-positive T cell gated events with the forward and side light-scatter characteristics of intact lymphocytes. Please note that we have observed considerable donor-to-donor variation in the proportion of CD197 CCR7 -negative CD4-positive lymphocytes. Plot 4: The two-parameter pseudocolor density plot showing CD197 CCR7 staining versus CD45RA was derived from CD8-positive T cell gated events with the forward and side light-scatter characteristics of intact lymphocytes. Show More Multicolor flow cytometric analysis of CD197 CCR7 on Human peripheral blood leukocytes and lymphocytes Human whole blood was stained with BD Horizon BV421 Mouse Anti-Human CD4 Cat. No. 562424 , BD Horizon BUV395 Mouse Anti-Human CD8 Cat. No. 563795 , APC Mouse Anti-Human CD45RA Cat. No. 550855 antibodies, and with either BD Horizon RB613 Mouse IgG1, kappa Isotype Control Cat. No. 571106 or BD Horizon RB613 Mouse Anti-Human CD197 CCR7 antibody Cat. No. 571209/571213 . The erythrocytes were lysed with BD FACS Lysing Solution Cat. No. 349202 . Flow cytometry and data analysis were performed using a BD FACSymphony A5 SE Cell Analyzer System and FlowJo Software. Plots 1 and 2: The bivariate pseudocolor density plots showing the correlated expression of CD197 CCR7 or Isotype control staining versus side light-scatter SSC-A signals were derived from gated events with the forward and side light-scatter characteristics of intact leukocytes. Plot 3: The two-parameter pseudocolor density plot showing the correlated expression of CD197 CCR7 versus CD45RA was derived from CD4-positive T cell gated events with the forward and side light-scatter characteristics of intact lymphocytes. Please note that we have observed considerable donor-to-donor variation in the proportion of CD197 CCR7 -negative CD4-positive lymphocytes. Plot 4: The two-parameter pseudocolor density plot showing CD197 CCR7 staining versus CD45RA was derived from CD8-positive T cell gated events with the forward and side light-scatter characteristics of intact lymphocytes.

More from BDB Bioscience

B
BD HorizonTM BV421 Mouse Anti-Human TIGIT
570445
reagents
B
BD OptiBuildTM BV750 Mouse Anti-Human HLA-DQ
746968
reagents
B
BD OptiBuildTM BV750 Rat Anti-Mouse CD93 (Early B Lineage)
746849
reagents
B
BD OptiBuildTM BV510 Rat Anti-Mouse Delta-Like Protein 1
744997
reagents
B
BD OptiBuildTM BUV805 Mouse Anti-Human CD275
748933
reagents
B
BD OptiBuildTM BV650 Rat Anti-Mouse CD23
740456
reagents
B
BD OptiBuildTM R718 Rat Anti-Mouse CCRL2
752021
reagents
B
BD PharmingenTM Mouse B Lymphocyte Activation Antibody Cocktail, with Isotype Control; PE-CyTM7 CD25, PE CD69, & FITC CD19
558064
reagents