

567253 ·
BDB Bioscience · Cat: 567253
Reach 3+ verified distributors
Manufacturer product page
bdbiosciences.com/en-us/products/reagents/flow-cytometry-rea...
Description
Analysis of Aire Expression Panel A. Multicolor flow cytometric analysis of Aire expression in thymic medullary epithelial cells mTECs from wild type Aire +/+ and knockout Aire / mice. Enriched preparation of mTECs prepared from wild type Aire +/+; Left 2 Plots and knockout Aire /; Right 2 Plots mice were fixed and permeabilized with BD Transcription Factor Buffer Set Cat. No. 562574/562725 . The cells were then stained with fluorescent antibodies specific for CD45, Ly51, and EpCAM, fluorescent Ulex europaeus agglutinin 1 UEA1 , FITC Anti-CD80 and either Alexa Fluor 647 Rat IgG2a kappa Isotype Control Cat. No. 557906 or Alexa Fluor 647 Rat Anti-Mouse Aire antibody Cat. No. 567253 at 0.25 mug/test. Aire expression was evaluated after gating for CD45- EpCAM+ Ly51 UEA1+ cells see reference J Immunol 2018 201:3244 for further details . The bivariate pseudocolor density plots showing the correlated expression of Aire or Ig Isotype control staining versus CD80 were derived from gated events with the forward and side light-scatter characteristics of intact mTECs. Flow cytometry and data analysis were performed using a BD FACSAria II Cell Analyzer System and BD FACSDiva Software. The flow data figures were kindly provided by Dr. Mitsuru Matsumotos laboratory . Panel B. Flow cytometric analysis of Aire expression in mouse Aire-transfected and -untransfected cells. The untransfected control 293F dotted line histogram and mouse Aire-transfected 293F solid line histogram cells were fixed and permeabilized with BD Transcription Factor Buffer Set. The cells were then stained with Alexa Fluor 647 Rat Anti-Mouse Aire antibody at 0.5 mug/test. Flow cytometric analysis was performed using a BD LSRFortessa X-20 Flow Cytometer System and FlowJo software. Data shown on this Technical Data Sheet are not lot specific. Analysis of Aire Expression Panel A. Multicolor flow cytometric analysis of Aire expression in thymic medullary epithelial cells mTECs from wild type Aire +/+ and knockout Aire / mice. Enriched preparation of mTECs prepared from wild type Aire +/+; Left 2 Plots and knockout Aire /; Right 2 Plots mice were fixed and permeabilized with BD Transcription Factor Buffer Set Cat. No. 562574/562725 . The cells were then stained with fluorescent antibodies specific for CD45, Ly51, and EpCAM, fluorescent Ulex europaeus agglutinin 1 UEA1 , FITC Anti-CD80 and either Alexa Fluor 647 Rat IgG2a kappa Isotype Control Cat. No. 557906 or Alexa Fluor 647 Rat Anti-Mouse Aire antibody Cat. No. 567253 at 0.25 mug/test. Aire expression was evaluated after gating for CD45- EpCAM+ Ly51 UEA1+ cells see reference J Immunol 2018 201:3244 for further details . The bivariate pseudocolor density plots showing the correlated expression of Aire or Ig Isotype control staining versus CD80 were derived from gated events with the forward and side light-scatter characteristics of intact mTECs. Flow cytometry and data analysis were performed using a BD FACSAria II Cell Analyzer System and BD FACSDiva Software. The flow data figures were kindly provided by Dr. Mitsuru Matsumotos laboratory . Panel B. Flow cytometric analysis of Aire expression in mouse Aire-transfected and -untransfected cells. The untransfected control 293F dotted line histogram and mouse Aire-transfected 293F solid line histogram cells were fixed and permeabilized with BD Transcription Factor Buffer Set. The cells were then stained with Alexa Fluor 647 Rat Anti-Mouse Aire antibody at 0.5 mug/test. Flow cytometric analysis was performed using a BD LSRFortessa X-20 Flow Cytometer System and FlowJo software. Data shown on this Technical Data Sheet are not lot specific. Show More Analysis of Aire Expression Panel A. Multicolor flow cytometric analysis of Aire expression in thymic medullary epithelial cells mTECs from wild type Aire +/+ and knockout Aire / mice. Enriched preparation of mTECs prepared from wild type Aire +/+; Left 2 Plots and knockout Aire /; Right 2 Plots mice were fixed and permeabilized with BD Transcription Factor Buffer Set Cat. No. 562574/562725 . The cells were then stained with fluorescent antibodies specific for CD45, Ly51, and EpCAM, fluorescent Ulex europaeus agglutinin 1 UEA1 , FITC Anti-CD80 and either Alexa Fluor 647 Rat IgG2a kappa Isotype Control Cat. No. 557906 or Alexa Fluor 647 Rat Anti-Mouse Aire antibody Cat. No. 567253 at 0.25 mug/test. Aire expression was evaluated after gating for CD45- EpCAM+ Ly51 UEA1+ cells see reference J Immunol 2018 201:3244 for further details . The bivariate pseudocolor density plots showing the correlated expression of Aire or Ig Isotype control staining versus CD80 were derived from gated events with the forward and side light-scatter characteristics of intact mTECs. Flow cytometry and data analysis were performed using a BD FACSAria II Cell Analyzer System and BD FACSDiva Software. The flow data figures were kindly provided by Dr. Mitsuru Matsumotos laboratory . Panel B. Flow cytometric analysis of Aire expression in mouse Aire-transfected and -untransfected cells. The untransfected control 293F dotted line histogram and mouse Aire-transfected 293F solid line histogram cells were fixed and permeabilized with BD Transcription Factor Buffer Set. The cells were then stained with Alexa Fluor 647 Rat Anti-Mouse Aire antibody at 0.5 mug/test. Flow cytometric analysis was performed using a BD LSRFortessa X-20 Flow Cytometer System and FlowJo software. Data shown on this Technical Data Sheet are not lot specific.







