

567332 · 100 Tests
BDB Bioscience · Cat: 567332
Reach 3+ verified distributors
Manufacturer product page
bdbiosciences.com/en-us/products/reagents/flow-cytometry-rea...Description
Two-color flow cytometric analysis of KIR2DL1/S1/S3/S5 CD158 expression on peripheral blood leucocyte populations. Whole blood was stained with BD Horizon BV421 Mouse Anti-Human CD56 antibody Cat. No. 562751/562752 and with either PerCP-Cy5.5 Mouse IgG2b, kappa Isotype Control Cat. No. 565380; Left Plots or PerCP-Cy5.5 Mouse Anti-Human KIR2DL1/S1/S3/S5 CD158 Cat. No. 567332/567333; Right Plots . Erythrocytes were lysed with BD Pharm Lyse Lysing Buffer Cat. No. 555899 . The bivariate pseudocolor density plots showing the corelated expression of KIR2DL1/S1/S3/S5 CD158 or Ig isotype control staining versus side light scatter signals for leucocyte populations Upper Plots or CD56 for lymphocytes Lower Plots were derived from gated events with the forward and side-light scatter characteristics of viable leucocytes or lymphocytes. Flow cytometry and data analysis were performed using a BD LSRFortessa X-20 Cell Analyzer System and FlowJo software. Two-color flow cytometric analysis of KIR2DL1/S1/S3/S5 CD158 expression on peripheral blood leucocyte populations. Whole blood was stained with BD Horizon BV421 Mouse Anti-Human CD56 antibody Cat. No. 562751/562752 and with either PerCP-Cy5.5 Mouse IgG2b, kappa Isotype Control Cat. No. 565380; Left Plots or PerCP-Cy5.5 Mouse Anti-Human KIR2DL1/S1/S3/S5 CD158 Cat. No. 567332/567333; Right Plots . Erythrocytes were lysed with BD Pharm Lyse Lysing Buffer Cat. No. 555899 . The bivariate pseudocolor density plots showing the corelated expression of KIR2DL1/S1/S3/S5 CD158 or Ig isotype control staining versus side light scatter signals for leucocyte populations Upper Plots or CD56 for lymphocytes Lower Plots were derived from gated events with the forward and side-light scatter characteristics of viable leucocytes or lymphocytes. Flow cytometry and data analysis were performed using a BD LSRFortessa X-20 Cell Analyzer System and FlowJo software. Show More Two-color flow cytometric analysis of KIR2DL1/S1/S3/S5 CD158 expression on peripheral blood leucocyte populations. Whole blood was stained with BD Horizon BV421 Mouse Anti-Human CD56 antibody Cat. No. 562751/562752 and with either PerCP-Cy5.5 Mouse IgG2b, kappa Isotype Control Cat. No. 565380; Left Plots or PerCP-Cy5.5 Mouse Anti-Human KIR2DL1/S1/S3/S5 CD158 Cat. No. 567332/567333; Right Plots . Erythrocytes were lysed with BD Pharm Lyse Lysing Buffer Cat. No. 555899 . The bivariate pseudocolor density plots showing the corelated expression of KIR2DL1/S1/S3/S5 CD158 or Ig isotype control staining versus side light scatter signals for leucocyte populations Upper Plots or CD56 for lymphocytes Lower Plots were derived from gated events with the forward and side-light scatter characteristics of viable leucocytes or lymphocytes. Flow cytometry and data analysis were performed using a BD LSRFortessa X-20 Cell Analyzer System and FlowJo software.







