BioMall
Brand Store/Takara/Lenti-XTM GoStixTM Plus
Lenti-XTM GoStixTM Plus
GENERAL CATALOGUE

Lenti-XTM GoStixTM Plus

631281 · 50 Tests

Takara · Cat: 631281

Reach 3+ verified distributors

Catalog No: 631281
Category: Viral transduction
Pack Size: 50 Tests
Brand: Takara

Description

Lenti-X GoStix Plus provide a rapid, simple, and effective method for instantly quantifying lentivirus in packaging cell supernatants. The test involves applying 20 mul of supernatant to a GoStix cassette and waiting 10 minutes for the appearance of test and control bands that indicate the presence of lentiviral p24. The results on the cassette can then be analyzed using a free smartphone app, which quantifies lentivirus titer by comparing the intensities of the test and control bands. The quantitative output from the Lenti-X GoStix App referred to as a GoStix Value, or GV can be used to compare virus amounts between different preparations in a manner similar to, but far easier and quicker than, an ELISA, and allows for calculation of actual IFU/ml using a reference virus. Cat. # 631281 includes sufficient reagents and cassettes for performing 50 tests. Our products are to be used forResearch Use Only. They may not be used for any other purpose, including, but not limited to, use in humans, therapeutic or diagnostic use, or commercial use of any kind. Our products may not be transferred to third parties, resold, modified for resale, or used to manufacture commercial products or to provide a service to third parties without our prior written approval. Back Back p24 production, GoStix Value, and IFU/ml are dependent on harvest time. ZsGreen1 lentivirus preparations were made in duplicate in accordance with the manufacturers instructions using Lenti-X Single Shots and harvested at the times indicated. At each timepoint, samples were analyzed for GV using Lenti-X GoStix Plus and virus dilutions were titrated on HT1080 cells to determine IFU/ml. In addition to showing that GV i.e., p24 accumulation and IFU/ml are dependent on harvest time, these data demonstrate that the ratio between GV and IFU/ml changes over time. Back Back Back Back Back

More from Takara

Lenti-XTM Packaging Single Shots (Integrase Deficient)
Lenti-XTM Packaging Single Shots (Integrase Deficient)
631277
Viral transduction
pRetroX-IRES-DsredExpress Vector
pRetroX-IRES-DsredExpress Vector
632521
Viral transduction
AAVpro Helper Free System (AAV2-LacZ)
AAVpro Helper Free System (AAV2-LacZ)
6655
Viral transduction
AAVpro Extraction Solution
AAVpro Extraction Solution
6235
Viral transduction
AAVpro Purification Kit Midi (All Serotypes)
AAVpro Purification Kit Midi (All Serotypes)
6675
Viral transduction
rLV.EF1.AmCyan1-9
rLV.EF1.AmCyan1-9
0039VCT
Viral transduction
Lenti-XTM p24 Rapid Titer Kit (Single Wash)
Lenti-XTM p24 Rapid Titer Kit (Single Wash)
631476
Viral transduction
Retro-XTM Universal Packaging System
Retro-XTM Universal Packaging System
631530
Viral transduction